Patient Monitor (BISTOS) Model: BT-750
৳ 160,000.00
Features:
* Product Name: Patient Monitor
* Model: BT-750
* Brand: BISTOS
* Origin: Korea
Specifications:
* Display Model: IP-4050 10.4″ wide TFT color LCD.
* Dimensions: 257 cm (W) x 236 cm (H) x 158 cm (D).
* Weight: 3.0 kg (excluding accessories).
* Resolution: 800 x 480 pixels.
* Waveforms: 6 max.
* Selectable 6 wave / 5 wave / 4 wave / 3 wave Display.
* Up to 3 hours use with a battery.
* Quick Start-Up: 72 hours of tabular and graphic trend data.
* RS-232 port or LAN.
* Multi-national Languages (7 languages).
* Central Monitoring System (UDP type).
Power Requirements:
o Voltage: AC 100 – 240 V / 50/60 Hz / 100 VA.
o Battery: One battery typically provides operating time of 3 hours per when fully changed with no printing, no external communication, and no audible alarm sound.
o Battery type: Li-ion (11.1 VDC / 220 mAH).
o Fuse: 250 V / 5 A.
Environmental Conditions:
o Operating Temperature: 50 to 104 °F.
o Operating Humidity: 15 to 90% RH, non-condensing.
o Storage Temperature: -4 to 122 °F.
ECG:
o LEAD: 3/5 leads, I, ii, iii, aVR , aVL, aVF, V (Chest Lead).
o HR (Heart Rate) Measurement Range: 20 to 300 bpm.
o HR Range Accuracy: ± 3 bpm or ± 3%, whichever is greater.
o Sweep Speed: 1.25 cm/s, 2.5 cm/s, 5 cm/s.
o Lead-Off Detection: Yes.
o CMRR: > 90 dB at 50 or 60 Hz.
o Gain: 0.5, 1, 2 cm/μ V.
Temperature Measurement:
o Method Type: Thermistor.
o Compatible With: YSI Series 400 Temperature Probes.
o Range: 50 to 113 °F.
Display Accuracy:
o ± 32.18 °F.
o ± 32.36 °F (Less than 77° F).
Respiration:
o Method Type: Trans-thoracic impedance.
o Leads: RA to LA.
o Range: 0 to 150 breaths/min.
o Accuracy: ± 2 breaths/min.
o Sweep Speed: 0.625 cm/s, 1.25 cm/s, 2.5 cm/s.
NIBP:
o Measurement Technology Oscillometric method.
o Pressure Display Range: 0 to 300 mmHg.
o Pressure Display Accuracy: Less than ± 3 mmHg.
Measurement Range (Adult / Child):
# Systolic: 50 to 225 mmHg.
# Diastolic: 30 to 220 mmHg.
# Mean: 40 to 235 mmHg.
Measurement Range (Infant / Neonate):
# Systolic: 30 to 130 mmHg.
# Diastolic: 20 to 100 mmHg.
# Mean: 25 to 120 mmHg.
o Measurement Mode: Manual, Auto, STAT.
o Auto Mode: 1, 3, 5, 10, 30, 60, 90, 120, 240 min.
SpO2: (Pulse Oximeter):
o Saturation Range: 0 – 100%.
o Pulse Rate Range: 20 to 300 bpm.
SpO2 Accuracy:
# Adult: 70 to 100% ± 2%.
# Neonate: 70 to 100% ± 3%.
# 0 – 69%: Unspecified.
o Pulse Rate Accuracy: 20 to 300 bpm ± 2%.
o Perfusion Range: 0.05 to 20%.
IBP:
o Channel: 2 channels.
o Method Type: Pressure transducer method.
o Pulse Rate Range: 20 to 250 bpm.
o Pulse Rate Accuracy: ± 1% or ± 1 bpm.
o Pressure Measurement Range: -50 to 300 mmHg.
o Parameter Displayed: P1, ABP, P2, CVP, PAP, LAP.
Reviews